{"product_id":"victron-lynx-distributor-m10","title":"Victron Lynx Distributor M10","description":"\u003cp data-end=\"586\" data-start=\"418\"\u003eThe \u003cstrong data-end=\"454\" data-start=\"422\"\u003eVictron Lynx Distributor M10\u003c\/strong\u003e is a professional modular DC distribution unit designed for advanced campervan, motorhome, marine, and off-grid electrical systems.\u003c\/p\u003e\n\u003cp data-end=\"933\" data-start=\"588\"\u003eIt combines a high-current DC busbar with intelligent fuse monitoring, allowing you to create a clean, safe, and organised electrical installation. The Lynx Distributor provides space for up to \u003cstrong data-end=\"818\" data-start=\"782\"\u003efour individual DC fuse circuits\u003c\/strong\u003e and monitors the status of each fuse with LED indicators on the front panel. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"988\" data-start=\"940\" data-section-id=\"11xqw5a\"\u003eClean \u0026amp; Professional DC Power Distribution\u003c\/h2\u003e\n\u003cp data-end=\"1095\" data-start=\"990\"\u003eThe Lynx Distributor makes it easy to connect and protect multiple DC components from a central location.\u003c\/p\u003e\n\u003cp data-end=\"1131\" data-start=\"1097\"\u003ePerfect for distributing power to:\u003c\/p\u003e\n\u003cul data-end=\"1290\" data-start=\"1133\"\u003e\n\u003cli data-end=\"1170\" data-start=\"1133\" data-section-id=\"ge4dbl\"\u003eVictron MultiPlus inverter\/chargers\u003c\/li\u003e\n\u003cli data-end=\"1197\" data-start=\"1171\" data-section-id=\"14t0fa6\"\u003eSolar charge controllers\u003c\/li\u003e\n\u003cli data-end=\"1214\" data-start=\"1198\" data-section-id=\"1u445pa\"\u003eDC-DC chargers\u003c\/li\u003e\n\u003cli data-end=\"1232\" data-start=\"1215\" data-section-id=\"nu9t5f\"\u003eBattery systems\u003c\/li\u003e\n\u003cli data-end=\"1264\" data-start=\"1233\" data-section-id=\"tm2lrr\"\u003eCampervan electrical circuits\u003c\/li\u003e\n\u003cli data-end=\"1290\" data-start=\"1265\" data-section-id=\"1gee2e1\"\u003eHigh-power DC equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1474\" data-start=\"1292\"\u003eThe modular design keeps wiring organised and creates a professional electrical cabinet layout for DIY van builders and professional installers. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"1509\" data-start=\"1481\" data-section-id=\"6w11xv\"\u003eHigh Current Capability\u003c\/h2\u003e\n\u003cp data-end=\"1581\" data-start=\"1511\"\u003eBuilt for demanding electrical systems, the Lynx Distributor supports:\u003c\/p\u003e\n\u003cul data-end=\"1725\" data-start=\"1583\"\u003e\n\u003cli data-end=\"1619\" data-start=\"1583\" data-section-id=\"968t3m\"\u003eUp to \u003cstrong data-end=\"1619\" data-start=\"1591\"\u003e1000A continuous current\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1654\" data-start=\"1620\" data-section-id=\"1d5jhmz\"\u003e12V, 24V and 48V battery systems\u003c\/li\u003e\n\u003cli data-end=\"1679\" data-start=\"1655\" data-section-id=\"1e1ofwx\"\u003eHeavy gauge DC cabling\u003c\/li\u003e\n\u003cli data-end=\"1725\" data-start=\"1680\" data-section-id=\"1soeph1\"\u003eHigh-capacity lithium battery installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1909\" data-start=\"1727\"\u003eThe M10 version uses larger busbar connections, making it suitable for high-current Victron installations where maximum reliability is required. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"1949\" data-start=\"1916\" data-section-id=\"1hrowwn\"\u003eIntelligent Fuse Monitoring\u003c\/h2\u003e\n\u003cp data-end=\"2056\" data-start=\"1951\"\u003eEach individual fuse position is monitored and displayed through LED indicators on the front of the unit.\u003c\/p\u003e\n\u003cp data-end=\"2067\" data-start=\"2058\"\u003eBenefits:\u003c\/p\u003e\n\u003cul data-end=\"2198\" data-start=\"2069\"\u003e\n\u003cli data-end=\"2099\" data-start=\"2069\" data-section-id=\"1f7lkmq\"\u003eQuickly identify blown fuses\u003c\/li\u003e\n\u003cli data-end=\"2124\" data-start=\"2100\" data-section-id=\"4119g9\"\u003eEasier troubleshooting\u003c\/li\u003e\n\u003cli data-end=\"2150\" data-start=\"2125\" data-section-id=\"1jw62mp\"\u003eIncreased system safety\u003c\/li\u003e\n\u003cli data-end=\"2198\" data-start=\"2151\" data-section-id=\"bj63f6\"\u003eCompatible with Victron GX monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2373\" data-start=\"2200\"\u003eWhen connected with compatible Victron monitoring equipment, system status can be integrated into your overall energy monitoring setup. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2800\" data-start=\"2664\"\u003e \u003c\/p\u003e\n\u003ch2 data-end=\"2837\" data-start=\"2807\" data-section-id=\"16p0b6y\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3435\" data-start=\"2839\"\u003e\n\u003cthead data-end=\"2864\" data-start=\"2839\"\u003e\n\u003ctr data-end=\"2864\" data-start=\"2839\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2855\" data-start=\"2839\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2864\" data-start=\"2855\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3435\" data-start=\"2875\"\u003e\n\u003ctr data-end=\"2915\" data-start=\"2875\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2883\" data-start=\"2875\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2915\" data-start=\"2883\"\u003eVictron Lynx Distributor M10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2965\" data-start=\"2916\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2931\" data-start=\"2916\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2965\" data-start=\"2931\"\u003eModular DC distribution module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2995\" data-start=\"2966\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2983\" data-start=\"2966\"\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2995\" data-start=\"2983\"\u003e9–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3036\" data-start=\"2996\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3017\" data-start=\"2996\"\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd data-end=\"3036\" data-start=\"3017\" data-col-size=\"sm\"\u003e12V \/ 24V \/ 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3075\" data-start=\"3037\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3066\" data-start=\"3037\"\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3075\" data-start=\"3066\"\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3117\" data-start=\"3076\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3093\" data-start=\"3076\"\u003eFuse Positions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3117\" data-start=\"3093\"\u003e4 × DC fuse circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3144\" data-start=\"3118\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3130\" data-start=\"3118\"\u003eFuse Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3144\" data-start=\"3130\"\u003eMEGA fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3181\" data-start=\"3145\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3163\" data-start=\"3145\"\u003eFuse Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3181\" data-start=\"3163\"\u003eLED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3209\" data-start=\"3182\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3202\" data-start=\"3182\"\u003eBusbar Connection\u003c\/td\u003e\n\u003ctd data-end=\"3209\" data-start=\"3202\" data-col-size=\"sm\"\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3241\" data-start=\"3210\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3235\" data-start=\"3210\"\u003eCable\/Fuse Connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3241\" data-start=\"3235\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3281\" data-start=\"3242\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3260\" data-start=\"3242\"\u003eBusbar Material\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3281\" data-start=\"3260\"\u003eTin-plated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3308\" data-start=\"3282\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3301\" data-start=\"3282\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-end=\"3308\" data-start=\"3301\" data-col-size=\"sm\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3343\" data-start=\"3309\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3322\" data-start=\"3309\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3343\" data-start=\"3322\"\u003e290 × 170 × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3363\" data-start=\"3344\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3353\" data-start=\"3344\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3363\" data-start=\"3353\"\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3406\" data-start=\"3364\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3388\" data-start=\"3364\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3406\" data-start=\"3388\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3435\" data-start=\"3407\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3427\" data-start=\"3407\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3435\" data-start=\"3427\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"3474\" data-start=\"3437\"\u003e \u003c\/p\u003e\n\u003ch2 data-end=\"3498\" data-start=\"3481\" data-section-id=\"1ie7g5a\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cul data-end=\"3834\" data-start=\"3500\"\u003e\n\u003cli data-end=\"3544\" data-start=\"3500\" data-section-id=\"1814aw1\"\u003eHigh-current DC distribution up to 1000A\u003c\/li\u003e\n\u003cli data-end=\"3580\" data-start=\"3545\" data-section-id=\"buwibb\"\u003eFour individually fused outputs\u003c\/li\u003e\n\u003cli data-end=\"3618\" data-start=\"3581\" data-section-id=\"8z2k6a\"\u003eIntegrated fuse status monitoring\u003c\/li\u003e\n\u003cli data-end=\"3657\" data-start=\"3619\" data-section-id=\"g1818r\"\u003eModular Victron Lynx system design\u003c\/li\u003e\n\u003cli data-end=\"3704\" data-start=\"3658\" data-section-id=\"8htfu0\"\u003eSuitable for lithium battery installations\u003c\/li\u003e\n\u003cli data-end=\"3747\" data-start=\"3705\" data-section-id=\"16appq0\"\u003eClean and professional wiring solution\u003c\/li\u003e\n\u003cli data-end=\"3790\" data-start=\"3748\" data-section-id=\"11rrlk4\"\u003eExpandable for larger campervan builds\u003c\/li\u003e\n\u003cli data-end=\"3834\" data-start=\"3791\" data-section-id=\"b29inf\"\u003eDesigned for demanding off-grid systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vanlife Shop","offers":[{"title":"Default Title","offer_id":57281285554549,"sku":null,"price":2450.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/3650\/2645\/files\/Lynx_20Power_20in_20_28M10_29_20_28front_29_2048x_43197b5e-5535-4e67-975b-e88542004b43.webp?v=1781167584","url":"https:\/\/www.vanlifeshop.se\/sv\/products\/victron-lynx-distributor-m10","provider":"Vanlife Shop","version":"1.0","type":"link"}